- Introduction to the Locator Fixed concept: A Comprehensive Guide for Dental Professionals
- What are the complete clinical requirements, maintenance protocols, and component logistics for Locator Fixed?
- How does Locator Fixed improve case acceptance and what phased treatment approaches are available?
- What makes ZEST unique, and how do its abutment options and prosthetic solutions compare?
- What are the analog and digital Locator workflows for lab and office processing?
- Home
- Products
- Full-Arch Solutions
- Zest LOCATOR® FIXED
Zest LOCATOR®
FIXED
The Zest LOCATOR® FIXED system utilizes established LOCATOR® abutments with rigid PEEK inserts and gold housings to deliver fixed prosthetic outcomes through identical clinical workflows.
This technology enables conversion of existing LOCATOR® patients to fixed prosthetics without abutment modification, requiring a minimum of four implants within 20-degree angulation parameters.
Positioned at a mid-tier cost fixed prosthetic price point for the patient, it addresses the treatment gap between cheaper overdenture options and the significantly more expensive screw-retained prosthetics, while reducing chair time by over 40 minutes compared to conventional fixed delivery protocols.
Our laboratory provides direct Zest component coordination and recommends Ivoclar materials for optimal clinical and cost outcomes.
Clinical Benefits
Workflow Efficiency:
- Identical workflow to the proven removable LOCATOR system
- Over 40 minutes average chair time savings vs. traditional fixed prosthetics
- Same prosthetic space requirements as a removable system
Treatment Flexibility:
- Converts existing LOCATOR patients to fixed without abutment changes
- Minimum 4 implants required with 9-11mm VDO
- Corrects up to 40 degrees of total implant divergence
Surgical Advantages:
- Less invasive procedure with reduced bone reduction requirements
- Universal compatibility with all major implant systems
Maintenance Benefits:
- Clinician-removable for easy hygiene access
- 5-minute maintenance appointments are delegable to hygiene staff
- PEEK rigid insert technology provides predictable retention
Patient Care:
- Staged treatment approach enables budget-friendly progression
- Immediate fixed prosthetic outcome using familiar components
Product Specifications

| Application | Less than 9-10mm space |
| Substructure | Metal Base |
| Materials | • Denture • Titanium bar • Locator® parts |
| Prosthetic Design | Denture reinforced with metal or FiberForce® |
| Minimum vertical space | 12mm |
| No. of patient visits | 4-6 |
| Esthetic Quality | ★★★★ |
| Wear | ★★★★ |
| Price | Click here to receive pricing |
Patient Case Study: From Diagnosis to LOCATOR Fixed Delivery
A partially dentate patient undergoes full-arch implant rehabilitation in a case where the treatment plan shifts multiple times — from screw-retained prosthesis to snap-on overdenture to a final mandibular Locator Fixed prosthesis — driven by anatomical findings, budget constraints, and new product availability.
The result: a monolithic zirconia Locator Fixed restoration on the mandible and a conventional implant-supported overdenture on the maxilla, achieved through a collaborative digital/analog workflow.
Zest LOCATOR® Fixed: Frequently Asked Questions
- How does Locator Fixed improve practice efficiency and salvage failed All-on-X cases?
- What are the failure prevention strategies and quality assurance measures needed for Locator Fixed?
- How do I measure and order a Locator correctly?
- What factors affect Locator Fixed pricing and how do material options compare?
- Locator Fixed Patient Case Study: From Patient Diagnosis to Full-Arch Delivery
Video Resources
Stud Attachments and Overdenture Bars Webinar
LOCATOR® Fixed: Case Presentation (Part 1)
LOCATOR® Fixed: Case Presentation (Part 2)
LOCATOR® Fixed: Case Presentation (Part 3)
LOCATOR® Fixed: Case Presentation (Part 4)
LOCATOR® Fixed: Patient Case 2
LOCATOR® Fixed: Patient Case 3 (Part 1 of 2)
LOCATOR® Fixed: Patient Case 3 (Part 2 of 2)
Stud Attachments and Overdenture Bars - Part 1
Stud Attachments and Overdenture Bars - Part 2
Stud Attachments and Overdenture Bars - Part 3
Full Arch Fixed Offerings - Product Comparison
| Esthetics | Wear | Price | Prosthetic Design | Substructure | Materials | |
|---|---|---|---|---|---|---|
| TLZ-IB Zirconia | ★★★★★ | ★★★★★ | $$$$ | FP3/FP2/FP1 | Full Zirconia | • Full zirconia • MiYO liquid porcelain • Titanium cylinders |
| TLZ-IB w/ Metal Substructure | ★★★★ | ★★★★★ | $$$$$ | FP3 | Titanium | • Full zirconia • MiYO liquid porcelain • Titanium substructure |
| NobelProcera® | ★★★★★ | ★★★★★ | $$$$ | FP3/FP2/FP1 | DOCERAM Nacera Pearl Zirconia | • DOCERAM Nacera Pearl Zirconia • MiYO liquid porcelain |
| G-CAM Graphenano | ★★★★ | ★★★ | $$ | FP3/FP2/FP1 | • Graphene nanoreinforced biopolymer G-CAM disc |
Upcoming Events
Full-Arch Unlocked: Mastering Oversentures, Fixed Full-Arch, & Restorative Materials
- Discuss Armamentarium for LOCATOR Abutments, LOCATOR Angled Abutments, LOCATOR Fixed & review of Chairside Restorative materials
- Learn protocol for Overdenture Therapy & review protocol for implant angle correction & introduction for FIXED Full arch therapy
- Discuss patient selection, case requirements, & troubleshooting
How can we help you today?
Can't find what you're looking for? No problem. Let us help.
ROE’s experts are dedicated to elevating your dental practice.
- Full-service national dental laboratory
- Comprehensive Certified Dental Laboratory (CDL) services
- Case planning support from 20+ Certified Dental Technicians
- Specialists in both fixed, removable, implant and full-arch dentistry
- Tailored support for all cases, from routine to complex
- National Association of Dental Laboratories (NADL) member
- Only FDA-approved materials used
- All products made in the USA
- Thousands of free online education materials
