- What is the NobelProcera Implant Bridge, and how is it different from a traditional titanium-base hybrid?
- What are the complete NobelProcera specifications, and which patients and case types is it indicated for?
- How does the NobelProcera angulated screw channel and "55 degrees of restorative freedom" help me clinically?
- What is the difference between the NobelProcera multi-unit abutment and implant-level connections?
- Home
- Products
- Full-Arch Solutions
- NobelProcera®
NobelProcera®
The NobelProcera Implant Bridge system represents over 12 years of refined full arch restoration technology, offering you a proven direct-to-implant approach that eliminates the complexity and failure risks associated with traditional titanium base systems.
With their latest 3.0 iteration, Nobel has perfected a cement-free delivery protocol using precision-milled zirconia or titanium frameworks that engage directly to your implants through proprietary angulated screw channel technology, providing up to 55 degrees of restorative freedom when combined with their multi-unit prosthetic screws.
The system's flexibility allows us to fabricate restorations in multiple design configurations—from full-contour to cut-back styles—using high-end zirconia in 10 precisely matched VITA shades, while their preload engineering philosophy ensures predictable long-term stability through mechanical retention rather than cement dependence.
Clinical Benefits: NobelProcera Implant Bridge
Elimination of Common Prosthetic Failures:
- Direct-to-implant interface eliminates titanium base complications, cement failures, and component delamination
- Preload engineering philosophy ensures mechanical retention through controlled screw tension rather than unpredictable adhesive bonds
- No more catastrophic failures from cracked or sheared titanium cylinders that compromise entire restorations
Superior Restorative Freedom:
- Up to 55° total angulation correction combining multi-unit abutment positioning with prosthetic screw angulation
- Addresses challenging implant positions without compromising structural integrity or requiring extensive surgical correction
- 25% smaller screw access holes improve esthetics while maintaining strength through optimized material distribution
Streamlined Clinical Delivery:
- Cement-free protocol eliminates cleanup procedures, tissue irritation, and peri-implant complications from cement retention
- Press-fit insert system with audible confirmation ensures proper seating and eliminates guesswork during delivery
- Proprietary Omnigrip instrumentation provides precise torque control with specialized drivers for different connection types
Enhanced Esthetic Outcomes:
- Multiple design configurations (full-contour, cut-back, thimble, framework) allow customized aesthetic approaches
- Smaller, optimally positioned screw channels maintain occlusal and facial esthetics without compromising access
Long-term Predictability:
- Retrieval and serviceability advantages of screw retention allow for maintenance without restoration destruction
- Industrial-grade manufacturing precision from proprietary large blanks ensures a consistent passive fit
- Comprehensive warranty support with QR code traceability provides patient confidence and practice protection
Universal Clinical Compatibility:
- Works with Nobel Biocare and other major implant systems for flexible treatment planning
- Accommodates 2-14 unit spans with up to 10 implant support for complex full arch rehabilitations
Product Specifications

| Application | • All, except heavy bruxers • Does not require metal copings • Must use Nobel-compatiblemulti-unit abutments |
| Days In Lab | 12 Days-In-Lab (does not include shipping) Schedule your patient return with our case delivery calculator |
| Substructure | DOCERAM Nacera® Pearl Zirconia |
| Materials | • DOCERAM Nacera®Pearl Zirconia • MiYO® liquid porcelain |
| Process | • Submit flask or duplicate prosthetic • Prototype Try-in • Final |
| Prosthetic Design | FP3 / FP2 / FP1 |
| Minimum vertical space | 10mm |
| No. of patient visits | 3-6 |
| Esthetic Quality | ★★★★★ |
| Wear | ★★★★★ |
| Price | Click here to receive pricing |
NobelProcera®: Frequently Asked Questions
- How is the NobelProcera bridge delivered and serviced at the chair?
- How does NobelProcera compare to ROE's other fixed full-arch options, and what design styles are available?
- What records does ROE need, and how do the records techniques work?
- How do I request pricing for NobelProcera, submit a case, and what support and warranty back the restoration?
Video Resources
Presenting NobelProcera: Full Arch Zirconia
Full Arch Options: Strength Guide
NobelProcera® Records Required for a Full Arch Bridge
The Process and Components for Seating a NobelProcera® Bridge
NobelProcera® – Capturing Records with a Flasking Technique
NobelProcera® Zirconia Implant Bridge
NobelProcera® Intro
NobelProcera® ASC
Full Arch Fixed Offerings - Product Comparison
| Esthetics | Wear | Price | Prosthetic Design | Substructure | Materials | |
|---|---|---|---|---|---|---|
| TLZ-IB Zirconia | ★★★★★ | ★★★★★ | $$$$ | FP3/FP2/FP1 | Full Zirconia | • Full zirconia • MiYO liquid porcelain • Titanium cylinders |
| TLZ-IB w/ Metal Substructure | ★★★★ | ★★★★★ | $$$$$ | FP3 | Titanium | • Full zirconia • MiYO liquid porcelain • Titanium substructure |
| NobelProcera® | ★★★★★ | ★★★★★ | $$$$ | FP3/FP2/FP1 | DOCERAM Nacera Pearl Zirconia | • DOCERAM Nacera Pearl Zirconia • MiYO liquid porcelain |
| G-CAM Graphenano | ★★★★ | ★★★ | $$ | FP3/FP2/FP1 | n/a | • Graphene nanoreinforced biopolymer G-CAM disc |
Upcoming Events
Full Arch Revision Success with GuidedSMILE
- Evaluate failed full-arch cases by identifying biological, mechanical, and prosthetic complications and gathering CBCT, scans, and restorative, transition-line, and phonetic assessments.
- Develop revision strategies that separate salvageable cases from those needing implant removal, bone reduction, or full reconstruction.
- Apply guided digital workflows using GuidedSMILE protocols to improve implant positioning, guide stability, and outcomes in compromised cases.
- Address complex anatomy by recognizing when alternative implant positioning, zygomatic or pterygoid anchorage, or soft-tissue management is needed.
FP1 Success with GuidedSMILE Natural
- Review the anatomical, prosthetic and patient factors used to determine whether a case is a candidate for FP1 or better served by FP3.
- Understand restoratively led planning for FP1 and how the final tooth position guides implant placement and MUA selection.
- Follow the GuidedSMILE Natural surgical sequence, including guided bone profiling of implant and pontic sites with the Universal Shaper Kit.
- Recognize the temporary bridge shaping and suturing considerations that influence soft-tissue healing and the final FP1 result.
Full Arch EXPRESS With LIVE Patients
- Full arch implant surgery is now essential
- Will learn: Scientific Principles, Case Selection, Modern Surgical Skills, Guided Surgery, Immediate Temporaries and Systematic Workflow
- 3 days of in-depth lectures
- 2 days of live patients
- Post-course support in the 3D Dentists Community
How can we help you today?
Can't find what you're looking for? No problem. Let us help.
ROE’s experts are dedicated to elevating your dental practice.
- Full-service national dental laboratory
- Comprehensive Certified Dental Laboratory (CDL) services
- Case planning support from 20+ Certified Dental Technicians
- Specialists in both fixed, removable, implant and full-arch dentistry
- Tailored support for all cases, from routine to complex
- National Association of Dental Laboratories (NADL) member
- Only FDA-approved materials used
- All products made in the USA
- Thousands of free online education materials
