What are the ArchBridge for Overdenture clinical workflows?
ArchBridge for Overdenture supports the digital pathways an overdenture practice actually encounters, whether the starting point is the patient's mouth, a prosthesis the patient is already wearing, or a stone model.
In each pathway the role of the ArchBridge component is the same: to place a recognizable reference geometry at each attachment position so the digital library can resolve that position accurately. Each pathway ends with a documented verification step before the case advances to design.
Workflow A: Healing denture to Fixed or Removable Overdenture
- Select the ideal overdenture abutments based on the healed tissue and seat onto each implant.
- Try in the denture and ensure a passive seat over the newly placed abutments. Relieve the denture where necessary to achieve a full seat. Once full seat is verified, remove the denture.
- Using medium body PVS, perform a wash to capture the tissue detail and abutment positions. Seat the denture in occlusion. Once the PVS is set, remove the denture.
- Capture a 360° extraoral scan of the washed denture with the IOS. Note: if having difficulty capturing the extraoral scan, see page 18 for more details.
- After the 360° scan of the washed prosthesis, scan the opposing along with any surrounding tissue, and bite.
- Capture a scan of the tissue and abutments. Be sure to include all tissue landmarks and vestibule.
- Place a scan body insert into each ArchBridge for Overdenture Scan Body, ensuring it is fully seated and flush with the base of the scan body.
- Seat one scan body onto each abutment. Rotate towards the center of the jaw, facing inwards, for the best scan results. Important: make sure the scan bodies are not touching each other and are fully seated.
- Capture an IOS scan of the scan bodies. Important: be sure to clearly capture the complete round head of the scan body where it is attached to the abutment.
- Choose ROE Dental Lab on your scanner portal and upload the following .STL files:
- Bite and opposing scan
- Tissue scan
- ArchBridge™ intraoral scan
- 360° denture scan
Workflow B: Existing Overdenture: Replace or Convert to Fixed Overdenture
- Using medium body PVS, perform a wash capturing the tissue detail and abutment positions. Seat the denture in occlusion. Once the PVS is set, remove the denture.
- Capture a 360° extraoral scan of the washed denture with the IOS. Note: if having difficulty capturing the extraoral scan, see page 18 for more details.
- After the 360° scan of the washed prosthesis, scan the opposing along with any surrounding tissue, and bite.
- Capture a scan of the tissue and abutments. Be sure to include all tissue landmarks and vestibule.
- Place a scan body insert into each ArchBridge for Overdenture Scan Body, ensuring it is fully seated and flush with the base of the scan body.
- Seat one scan body onto each abutment. Rotate towards the center of the jaw, facing inwards, for best scan results. Important: make sure the scan bodies are not touching each other and are fully seated.
- Capture an IOS scan of the scan bodies. Important: be sure to clearly capture the complete round head of the scan body where it is attached to the abutment.
- Choose ROE Dental Lab on your scanner portal and upload the following .STL files:
- Bite and opposing scan
- Tissue scan
- ArchBridge™ intraoral scan
- 360° denture scan
Workflow C: Extraoral capture using ScanAnalogs
Use this pathway when working from an existing prosthesis or a stone model.
- Remove the existing retention inserts and replace them with black processing inserts.
- Place a ScanAnalog into each LOCATOR site and ensure full seat. Note: ensure that the shiny side of the two-sided analog is inserted into the denture.
- Place a white LOCATOR Processing Spacer into each ArchBridge for Overdenture Scan Body, ensuring it is fully seated and flush with the base of the scan body.
- Seat one scan body onto each ScanAnalog. Rotate toward the center of the denture, facing inward, for ease of scanability. Important: scan bodies must not touch each other and must be fully seated.
- Capture a 360 degree extraoral scan of the scan bodies with the IOS, clearly capturing the complete round head of each scan body.
If you have difficulty capturing an extraoral scan in Workflow A or B, use the ScanAnalog method described here.
Files to submit for every pathway
| STL file | Purpose |
|---|---|
| Bite and opposing scan | Establishes occlusal relationship |
| Tissue scan | Captures tissue landmarks, vestibule, and abutments |
| ArchBridge intraoral scan | Resolves attachment position and orientation |
| 360 degree denture scan | Captures the relined or existing prosthesis |
Also upload patient photographs and a completed Rx.
Additional Resources
For more information concerning ArchBridge for Overdenture:
Contact Information
For help with your next case, contact ROE Dental Laboratory:
- Phone: (216) 663-2233
- Email: info@roedentallab.com