What are the specifications of G-CAM Graphenano?

G-CAM is the value tier among ROE's fixed full-arch offerings, trading the very highest wear rating for a lighter, gentler, more affordable prosthesis. The specifications, drawn from ROE's product comparison and restorative guide:

Specification Detail
Application All patient types except heavy bruxers; lightweight prosthesis
Substructure Milled fiber-composite or titanium bar (ROE's restorative guide lists Trilor® or titanium)
Signature material Graphene-nanoreinforced biopolymer G-CAM disc, with milled teeth bonded to the substructure
Prosthetic design FP1, FP2, or FP3
Minimum vertical space 15 mm (per ROE's restorative guide)
Esthetic quality 4 out of 5
Wear 3 out of 5
Relative price $$ (the most economical of ROE's fixed full-arch options)

A note on vertical space: At a 15 mm minimum, G-CAM calls for more restorative room than ROE's zirconia options, which sit at roughly 10 to 12 mm. Identify available space early in planning, because it influences whether this design is feasible. Because available space and the ideal material interact, confirm the final design with ROE during case planning. Pricing is provided on request through the Get Pricing page.

 