Skip to content
  • There are no suggestions because the search field is empty.

What are the LOCATOR Overdenture specifications?

Specification Detail
Prosthesis type Implant-retained removable overdenture (LOCATOR attachment-retained)
Implant interface Narrow-diameter implants (2.4–2.9 mm) with pivoting LOCATOR attachments (up to 40° divergence)
Substructure Metal base (metal reinforcement embedded in the denture base)
Prosthetic design Denture reinforced with metal or FiberForce®
Materials Denture, metal substructure, LOCATOR attachment parts ⚠ (product page spec list also references a "titanium bar" — confirm wording)
Application Less than 9–10 mm space (per product page)
Minimum vertical space 12 mm
Patient visits (est.) 4–6
Lab days 9 (does not include shipping)
Esthetic quality ★★★★
Wear ★★★★
Price By quote (request pricing from ROE)

 

Additional Resources

For more information concerning the ZEST Locator Fixed:

Contact Information

For help with a Locator Fixed solution for your next case, contact ROE Dental Laboratory: