What to do if the temp cylinders are touching the sides of the holes?
First check implant rotation on angled implants – best course of action is to rotate the implant until the Temp Cylinder is straight and parallel with the others. This means remove the MUA and use a hand driver to slightly adjust. Implant must be indexed precisely according to the Hex on the Osteotomy Guide for straight temp cylinders. Goal with CHROME is to deliver all parallel Temp Cylinders. This creates simple pick-up at surgery and ideal screw access in the final. If the Temp Cylinders are going to be picked up in the current tipped position, then adjust the prosthetic slightly to remove the contact. Sometimes the Temp Cylinders can be seated from the top down. In other words, seat the prosthetic on the remaining cylinders and deliver the crooked cylinder from the occlusal hole. If not, again, adjust the shaft of the prosthetic to accommodate. DO not over adjust, need 3mm from shaft to outside of prosthetic.